Checks the link-state of net-ports.
$ check_netapp_netport -H <host> [--ok-state=<regex>] [...] [--help]
This plugin checks each net-ports link-state. Alarms if link-state is not up (default).
sim96cluster::> network port show
Node: sim96cluster-01
Speed(Mbps) Health
Port IPspace Broadcast Domain Link MTU Admin/Oper Status
--------- ------------ ---------------- ---- ---- ----------- --------
e0a Default Default up 1500 auto/1000 healthy
e0b Default Default down 1500 auto/- -
e0c Default Default up 1500 auto/1000 healthy
e0d Default Default up 1500 auto/1000 healthy
4 entries were displayed.
./check_netapp_netport -H sim96
NETAPP NETPORT OK - 4 netports checked
sim96cluster-01.e0b.physical: up, enabled
sim96cluster-01.e0d.physical: up, enabled
sim96cluster-01.e0c.physical: up, enabled
sim96cluster-01.e0a.physical: up, enabled
Checks all net-ports. Would return CRITICAL if the state is not ‘up’
./check_netapp_netport -H sim96
NETAPP NETPORT CRITICAL - 4 netports checked, 1 CRITICAL
sim96cluster-01.e0b.physical: down (CRITICAL), enabled
sim96cluster-01.e0d.physical: up, enabled
sim96cluster-01.e0c.physical: up, enabled
sim96cluster-01.e0a.physical: up, enabled
Same as above - but one of the ports is down.
Disabling a port is often not possible via the filer’s UI. So this switch might be useless on some systems.
./check_netapp_netport -H sim96
NETAPP NETPORT CRITICAL - 4 netports checked, 1 CRITICAL
sim96cluster-01.e0b.physical: down (CRITICAL), disabled
sim96cluster-01.e0d.physical: up, enabled
sim96cluster-01.e0c.physical: up, enabled
sim96cluster-01.e0a.physical: up, enabled
One of the ports is still down but disabled as well. This allows to skip it by means of the --ignore-disabled switch:
./check_netapp_netport -H sim96 --ignore-disabled
NETAPP NETPORT OK - 3 netports checked
Skipped 1 disabled instances (enabled: false)
sim96cluster-01.e0d.physical: up, enabled
sim96cluster-01.e0c.physical: up, enabled
sim96cluster-01.e0a.physical: up, enabled
With --exclude and --include ports can be excluded or included depending on their instance name <node>.<port>.<type> (e.g. node-01.e0a.physical, node-01.a0a.lag). Since these parameters also accept a regular expression specific nodes can be tested. (See also Regular Expressions)
./check_netapp_netport -H sim96 --include='~\.e0a\.'
NETAPP NETPORT OK - 1 netport checked
3 instances skipped because of --include/--exclude settings
sim96cluster-01.e0a.physical: up, enabled
Checks exactly one net-port.
./check_netapp_netport -H mycluster --include='~^mycluster-01\.'
NETAPP NETPORT OK - 4 netports checked
mycluster-01.e0b.physical: up, enabled
mycluster-01.e0d.physical: up, enabled
mycluster-01.e0c.physical: up, enabled
mycluster-01.e0a.physical: up, enabled
Checks only the net-ports on node “01”.
For partial degradation monitoring of interface groups (e.g. detecting when an ifgrp is up but has lost some member ports), use the dedicated check_netapp_ifgrp check. It compares active ports against member ports and can alarm on partial failures — something check_netapp_netport cannot detect.
check_netapp_netport can see interface groups but only reports their overall link-state (up or down). To avoid duplicate alerts, you can exclude ifgrps from this check:
./check_netapp_netport -H cluster1
NETAPP NETPORT CRITICAL - 9 netports checked, 1 CRITICAL
cluster1-01.e0a.physical: up, enabled
cluster1-01.e0b.physical: up, enabled
cluster1-01.e0c.physical: up, enabled
cluster1-01.e0d.physical: up, enabled
cluster1-02.e0a.physical: up, enabled
cluster1-02.e0b.physical: up, enabled
cluster1-02.e0c.physical: up, enabled
cluster1-02.e0d.physical: up, enabled
cluster1-01.a0a.lag: down (CRITICAL), enabled
Exclude interface groups and monitor them separately with check_netapp_ifgrp:
./check_netapp_netport -H cluster1 --exclude='~lag$'
NETAPP NETPORT OK - 8 netports checked
1 instances skipped because of --include/--exclude settings
cluster1-01.e0a.physical: up, enabled
cluster1-01.e0b.physical: up, enabled
cluster1-01.e0c.physical: up, enabled
cluster1-01.e0d.physical: up, enabled
cluster1-02.e0a.physical: up, enabled
cluster1-02.e0b.physical: up, enabled
cluster1-02.e0c.physical: up, enabled
cluster1-02.e0d.physical: up, enabled